Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (2024)

Contents

  • 1 INTRODUCTION
  • 2 FEATURES
    • 2.1 LCD SCREEN
  • 3 VIEWING BATTERY STATUS
  • 4 CHARGING / RECHARGING
    • 4.1 CHARGING/RECHARGING USING THE 120 VOLT AC/USB CHARGING ADAPTER
    • 4.2 CHARGING/RECHARGING USING THE 12V DC/USB CHARGING ADAPTER
    • 4.3 CHARGING/RECHARGING USING THE USB CHARGING CABLE AND A DEVICE WITH A USB POWER PORT (NOT SUPPLIED)
  • 5 OPERATING INSTRUCTIONS
    • 5.1 JUMP-STARTING USING THE SMART CABLES
      • 5.1.1 Battery Clamp Connection Precautions
      • 5.1.2 Connecting the Jump-Starter Using the Included Battery Clamps
      • 5.1.3 Procedure
    • 5.2 OPERATING THE USB PORTS AND LED LIGHT
      • 5.2.1 USB Fault Conditions
    • 5.3 OPERATING THE 120V AC/USB CHARGING ADAPTER'S USB PORT
    • 5.4 OPERATING THE 12V DC/USB CHARGING ADAPTER'S USB PORT
  • 6 CARE AND MAINTENANCE
    • 6.1 BATTERY
      • 6.1.1 Safe Battery Disposal
    • 6.2 REPLACING THE FUSE IN THE 12V DC/USB CHARGING ADAPTER
  • 7 TROUBLESHOOTING
  • 8 ACCESSORIES
  • 9 SERVICE INFORMATION
  • 10 SPECIFICATIONS
  • 11 SAFETY GUIDELINES / DEFINITIONS
  • 12 IMPORTANT SAFETY INSTRUCTIONS
    • 12.1 GENERAL SAFETY WARNINGS AND INSTRUCTIONS
    • 12.2 SPECIFIC SAFETY INSTRUCTIONS FOR LITHIUM BATTERIES
      • 12.2.1 Battery Charging and Capacity
      • 12.2.2 Transportation of Lithium Batteries
    • 12.3 SPECIFIC SAFETY INSTRUCTIONS FOR JUMP-STARTERS
    • 12.4 INSTRUCTIONS PERTAINING TO THE 12V DC/USB CHARGING ADAPTER
    • 12.5 INSTRUCTIONS PERTAINING TO THE USB PORTS
    • 12.6 PERSONAL SAFETY
  • 13 Documents / Resources
    • 13.1 References
    • 13.2 Download manual

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (1)

SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE.

INTRODUCTION

Read this Instruction Manual and follow the instructions carefully before using this unit.

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (2)

  • Jump-starters are designed for use on small to mid-sized vehicle batteries.
  • Several factors can affect a jump-starter's ability to start a vehicle's battery, including, but not limited to the size of the battery, the temperature (hot or cold), whether the battery is damaged or defective, and whether the jump-starter itself is fully charged.
  • The jump-starter requires a minimum voltage to detect the correct connection before it will begin to start. If the vehicle battery voltage is below approximately 2 volts, it may not be able to detect connection and may not be able to start the vehicle. While this low battery voltage is rare it may occur under extreme conditions.

FEATURES

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (3)

  1. Lithium Battery Status Indicator (LCD Screen)
  2. USB/LED Power Button
  3. Smart Cables Port
  4. 3.1A USB Ports
  5. Smart Cables Controller
  6. Bi-Color Booster Status Indicator
  7. Smart Cables Connector
  8. Positive (+) Red Clamp
  9. Negative (–) Black Clamp
  10. USB Charging Cable
  11. LED Light (dual bulbs)
  12. 12V DC/USB Charging Adapter
  13. 12V DC/USB Charging Adapter LED Indicator
  14. 12V DC/USB Charging Adapter USB port
  15. 120V AC/USB Charging Adapter
  16. 120V AC/USB Charging Adapter USB port

LCD SCREEN

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (4)

  1. Battery Status Icon
  2. USB Icon
  3. Fault Icon

VIEWING BATTERY STATUS

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (5)

The Battery Status Icon indicates the battery charge level as follows:

  • If the battery charge level is at full capacity, four solid bars will display.
  • If the battery is partially charged, two or three solid bars will display.
  • If the battery is nearly empty, one solid bar will display. The unit should be charged at this time.
  • If the battery is completely empty, four blank bars will display. The unit MUST be charged at this time or the unit's built-in low voltage protection will activate. The empty Battery Status Icon will light for a short period of time before automatic shut down. The unit will not operate until the battery is recharged.

CHARGING / RECHARGING

This unit is shipped in a partially charged state. Charge unit after purchase and BEFORE first use and after each use until the Battery Status Icon shows 4 solid bars when the USB/LED Power Button is pressed (with the adapter unplugged from the unit).

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (6)
When the unit is not in use, we recommend that the battery is charged at least every 3 to 6 months.

NOTICE – To avoid the risk of property damage: Failure to keep the battery charged will cause permanent damage and result in poor performance.

NOTES:

  • When one of the USB ports is used in the charging process, the other USB port will have no output. Pressing the Power Button during the charging process will only control the LED Light.
  • When the unit battery is fully charged, the charging process will terminate and the unit will automatically shut down.
  • 2A USB is required in order to recharge the unit (2A AC and DC charging adapters included).
  • During the charging process, the unit will stop charging if the battery of the unit is overheated due to extensive use or recharging and will automatically resume after a cool down period. The LCD Display will show the Battery Icon and the flashing Fault Icon.
    Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (7)

CHARGING/RECHARGING USING THE 120 VOLT AC/USB CHARGING ADAPTER

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (8)
Always connect the 120V AC/USB Charging Adapter to the 120 Volt AC power source (using the USB Charging Cable) BEFORE connecting it to the unit.

  1. Make sure the USB/LED Power Button is turned off (the LCD Screen is not lit).
  2. Insert one end of the USB Charging Cable into the 120V AC/USB Charging Adapter.
  3. Insert the 120V AC/USB Charging Adapter into a standard 120 volt AC wall outlet or a functioning 120 volt AC power source.
  4. Lift up the protective cover of the USB ports. Insert the other end of the USB Charging Cable into the one of dual USB ports on the unit. When the unit is properly connected to an AC power source, the backlit LCD screen will display the following:
    Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (9)
    The bars on the Battery Status Icon will change from empty to solid (bottom to top) repeatedly to indicate the unit is charging.
  5. Charge for approximately 6 hours or until the unit automatically shuts down.
  6. Unplug the 120V AC/USB Charging Adapter from the 120 volt AC power source, and then disconnect the USB Charging Cable from the 120V AC/USB Charging Adapter and the unit.
  7. Press the USB/LED Power Button to turn the unit on. If the Battery Status Icon shows 4 solid bars, the unit battery is fully charged.
  8. When charging is complete, store the 120V AC/USB Charging Adapter and USB Charging Cable in a safe place.

CHARGING/RECHARGING USING THE 12V DC/USB CHARGING ADAPTER

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (10)
Always connect the 12V DC/USB Charging Adapter to the 12 Volt DC power source (using the USB Charging Cable) BEFORE connecting it to the unit.

  1. Make sure the USB/LED Power Button is turned off (the LCD Screen is not lit).
  2. Insert one end of the USB Charging Cable into the 12V DC/USB Charging Adapter.
  3. Insert the 12V DC/USB Charging Adapter into a vehicle's 12 volt DC accessory outlet or other functioning 12 volt DC power source. The LE indicator on the 12V DC/USB Charging Adapter will light green when it is properly plugged into the 12 volt DC power source.
    Note: Some vehicles require that the ignition be switched to the accessory outlet position in order to power the accessory outlet.
  4. Lift up the protective cover of the USB ports. Insert the other end of the USB Charging Cable into the one of dual USB ports on the unit. When the unit is properly connected, the backlit LCD Screen will display the following:
    Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (11)
    The bars on the Battery Status Icon will change from empty to solid (bottom to top) repeatedly to indicate the unit is charging.
  5. Charge until the unit automatically shuts down.
  6. Unplug the 12V DC/USB Charging Adapter from the 12 volt DC power source, and then disconnect the USB Charging Cable from the 12V DC/USB Charging Adapter and the unit.
  7. Press the USB/LED Power Button to turn the unit on. If the Battery Status Icon shows 4 solid bars, the unit battery is fully charged.
  8. When charging is complete, store the 12V DC/USB Charging Adapter and USB Charging Cable in a safe place.

CHARGING/RECHARGING USING THE USB CHARGING CABLE AND A DEVICE WITH A USB POWER PORT (NOT SUPPLIED)

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (12)
Always connect the USB Charging Cable to the external device's USB power port BEFORE connecting it to the unit. A 2A USB power source is required in order to recharge the unit.

  1. Make sure the USB/LED Power Button is turned off (the LCD Screen is not lit).
  2. Insert one end of the USB Charging Cable into an external device's functional USB power port.
  3. Lift up the protective cover of the USB ports. Insert the other end of the USB Charging Cable into the one of dual USB ports on the unit.
  4. When the unit is properly connected, the backlit LCD screen will display the following:
    Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (13)
    The bars on the Battery Status Icon will change from empty to solid (bottom to top) repeatedly to indicate the unit is charging.
  5. Charge until the unit automatically shuts down.
  6. Disconnect the USB charging cable from the device's USB power port and the unit.
  7. Press the Power Button to turn the unit on. If the Battery Status Icon shows 4 solid bars, the unit battery is fully charged.
  8. When charging is complete, store the USB Charging Cable in safe place.

OPERATING INSTRUCTIONS

JUMP-STARTING USING THE SMART CABLES

Battery Clamp Connection Precautions

  • Connect and disconnect the battery clamps only after unplugging the power source.
  • Make sure the engine is not running when connecting or disconnecting the battery clamps.
  • Never allow clamps to touch each other.
  • Attach clamps to battery and chassis as indicated in the section "Connecting the Jump-Starter Using the Included Battery Clamps".

Connecting the Jump-Starter Using the Included Battery Clamps

  1. Position the Smart Cables Controller to reduce risk of damage by the car hood, doors, or moving engine parts.
  2. Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to persons.
  3. Check polarity of battery posts. The positive (POS, P, +) battery post usually has larger diameter than the negative (NEG, N, –) post.
  4. Connect the Smart Cables Connector to the Smart Cables Port. Be especially careful, since both the Connector and Controller are "live."
  5. Connect the positive (RED) clamp from the jump-starter to the positive (POS, P, +) ungrounded battery post. Connect the negative (BLACK) clamp to the negative (NEG, N, –) battery post, the vehicle chassis or engine block away from the battery. Do not connect the clamp to the carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gauge metal part of the frame or engine block.
    Note: If the battery clamps are incorrectly connected with regard to polarity, the Bi-Color Jump-Starter Status Indicator will light red until the clamps are disconnected. Remove the clamps and then reconnect them with correct polarity.
  6. When disconnecting the jump-starter, first remove the negative BLACK (–) clamp from the negative battery post or the vehicle chassis, and then remove the positive RED (+) clamp from the positive battery post. Disconnect the double barrel connector of the Smart Cables Controller from the Smart Cables Port of unit. Store the Smart Cables Controller in a safe place.

Procedure

Take the following steps, observing all cautions and warnings in the "Important Safety Instructions" section at the front of this manual.

  1. Turn off vehicle ignition and all accessories (radio, A/C, lights, connected cell phone chargers, etc.). Place vehicle in "park" and set the emergency brake.
  2. Make sure all the unit functions are turned off (the LCD Screen is not lit) and the USB Charging Cable is NOT connected.
  3. Lift up the protective cover of the unit's Smart Cables Port. Insert the double-barrel Smart Cables Connector into the Smart Cables Port on the unit.
  4. Set up the unit as described in the "Connecting the Jump-starter Using Included Battery Clamps" section, observing all warnings and cautions in the "Important Safety Instructions" section.
  5. When the unit is properly connected, the Bi-Color Status Indicator on the Smart Cables Controller will light green.
  6. Turn on the ignition and crank the engine in 5-6 second bursts until the engine starts.
  7. When the process is completed, disconnect the jump-starter. First remove the negative BLACK (–) clamp from vehicle chassis, and then remove the positive RED (+) clamp from the positive battery post. Disconnect the double barrel Smart Cables Connector from the Smart Cables Port.
  8. Store the Smart Cables Controller in a safe place.
  9. Recharge the unit fully.

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (14)
If the battery clamps are incorrectly connected with regard to polarity, the Bi-Color LED Status Indicator will light red until the clamps are disconnected. Remove the clamps and then reconnect them with correct polarity.

If the voltage of the unit's internal lithium battery is low and has insufficient output power, the Bi-Color LED Status Indicator will light red. Disconnect the unit and fully charge following the directions in the "Charging / Recharging" section.

If the Smart Cables Controller is overheated, the Bi-Color LED Status Indicator will light red. Disconnect the Battery Clamps and allow the unit to cool down for a period before resuming any operation.

If the cranking current and/or time period exceeds the unit's parameters, the Bi-Color LED Status Indicator will flash red for 50 seconds (a cooling down period) before lighting green again (resuming normal operation).

NOTICE – To avoid the risk of property damage:

  • If the vehicle doesn't start after the first attempt, allow a resting/cooling period of 4 to 5 minutes before making a second attempt. If a second attempt doesn't start the vehicle, discontinue use and look for other problems that need to be corrected. The battery may be damaged.
  • NEVER attempt to use the unit to start a vehicle while it is in charging mode.
  • Using the jump-starter without a car battery installed in the vehicle will damage the vehicle's electrical system.

OPERATING THE USB PORTS AND LED LIGHT

The dual USB Ports and the dual LED Light are located on the top and the back of the unit respectively, Both are controlled by the USB/LED Power Button.

  1. Press the USB/LED Power Button on the unit once. The LCD screen will display the Battery Status Icon and the USB Icon, indicating the USB ports are both ready to use.
  2. Lift up the protective cover of the USB ports. Plug the USB-powered device into the USB power port(s) and operate normally.
  3. Press the USB/LED Power Button a second time. The LCD screen will display the Battery Status Icon and the USB Icon. The LED light will turn on (and the USB Ports remain active).
  4. Press the USB/LED Power Button a third time to turn off both functions.

Periodically check the unit's battery status on the LCD screen. Four solid bars in the Battery Status Icon indicate a full battery. When the battery level is nearly empty (only one solid bar) or completely empty (no bars), the unit must be recharged or the unit's built-in low voltage protection will activate briefly before automatic shut down occurs.

Make sure all the unit functions are turn off when it is being recharged or stored.

USB Fault Conditions

  • When the USB Ports are in use, the unit will monitor for the following USB fault conditions (on both USB Ports).
  • If a Low Battery Voltage Fault occurs, the LCD screen will display the following:
    Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (15)
    The empty Battery Status Icon will light solid for one minute before automatic shut down occurs.
  • If the battery of the unit overheats or is too cold, the LCD screen will display the following:
    Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (16)
    The Battery Status Icon will light solid. The Fault Icon will flash for one minute before automatic shut down occurs.
  • If an Overload Fault or Short-circuit occurs, the unit will automatically shut down immediately.

In any of these cases, disconnect the USB-powered device(s) immediately.

  • Make sure the unit does not need to be recharged.
  • Allow the unit to cool down for several minutes before attempting to use the USB Ports again.
  • If a fault occurs again, make sure that the total draw of all USB devices plugged into the USB Ports does not exceed 3.1A (5V).
  • If an individual USB device is within specifications and the fault occurs, have the USB device checked for malfunction and do not continue to use it with these USB Ports.

Notes: This unit's USB Ports do not support data communication. They only provide power to external USB-powered devices. The USB Ports provide a total of 3.1A (5V).
Some USB-powered household electronics may not operate with this USB port. Check the manual of the corresponding electronic device to confirm that it can be used with this type of USB port.

OPERATING THE 120V AC/USB CHARGING ADAPTER'S USB PORT

Plug the 120V AC/USB Charging Adapter into a (powered) standard North American 120 volt 60Hz outlet. Simply plug a USB device into the USB outlet and operate normally.

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (17)
To reduce the risk of injury or property damage: Always plug the 120V AC/USB charging adapter to the standard North American 120 volt 60Hz outlet before plugging any devices into it.

OPERATING THE 12V DC/USB CHARGING ADAPTER'S USB PORT

Plug the 12V DC/USB Charging Adapter into a vehicle's 12 volt DC accessory outlet or other functioning 12 volt DC power source. The LED indicator on the 12V DC/USB Charging Adapter LED Indicator will light green to show that it is properly connected. Simply plug a USB device into the USB outlet and operate normally.

Note: Some vehicles require that the ignition be switched to the accessory outlet position in order to power the accessory outlet.

CARE AND MAINTENANCE

All batteries lose energy from self-discharge over time and more rapidly at higher temperatures. When the unit is not in use, we recommend that the battery is charged at least every 3-6 months.

From time to time wipe the outside of the appliance with a soft cloth. Do not immerse the appliance in water.

There are no user-replaceable parts. Periodically inspect the condition of adapters, connectors and wires. Contact manufacturer to replace any components that have become worn or broken.

BATTERY

Please be advised that the battery is designed to last the service life of the unit and is not replaceable, removable or serviceable. Service life is dependent on a number of factors including but not limited to the number of recharge cycles, and proper care and maintenance of the battery by the end user. Contact manufacturer for any information you may need.

Safe Battery Disposal

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (18)

Contains a lithium battery, which must be disposed of properly. Recycling is required. Failure to comply with local, state and federal regulations can result in fines, or imprisonment.

Please recycle.

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (19)

  • Do not dispose of the battery in fire as this may result in an explosion.
  • Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting (shorting can result in injury or fire).
  • Do not expose battery to fire or intense heat as it may explode.

REPLACING THE FUSE IN THE 12V DC/USB CHARGING ADAPTER

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (20)

  1. Unscrew the end cap of the DC plug (counterclockwise).
  2. Remove spring center contact and fuse.
  3. Check fuse with a continuity checker.
  4. If blown, locate a replacement 2 amp fuse.
  5. Replace the fuse, spring, contact and end cap.
  6. Screw end cap clockwise until it is finger tight – DO NOT OVER-TIGHTEN.
  7. Test for proper operation of the 12V DC Charging Adapter.

TROUBLESHOOTING

The Jump-Starter / Power Bank will not charge

  • Check that all the unit functions are all turned off (the LCD Screen is not lit).
  • Check that the USB Charging Cable is properly connected to either the 12V DC/USB charging adapter or the 120V AC/USB charging adapter, and to the unit.
  • Check the connection to the AC or DC power source. Make sure there is good contact.
  • Confirm that there is functioning AC or DC current.
  • Confirm that the unit is plugged into a 2A USB power source.
  • Check the plug fuse in the 12V DC/USB Charging Adapter. Replace the fuse following the instructions in this manual, if necessary.
  • The unit may have shut down to protect the battery from overheating after a long period of operation or charging. Unplug the charging adapter from the power source and disconnect the USB charging cable from the unit. Allow the unit to cool down for a period before resuming charging.

The Jump-Starter will not start the vehicle

  • Check that all the unit functions are all turned off (the LCD Screen is not lit).
  • Make sure a proper polarity cable connection has been established and the Bi-Color Booster Status Indicator on the Smart Cables Controller lights green.
  • The unit may be in over-current / over-time protection. Remove the clamps and restart after a cooling down period of approximately 30 minutes.
  • The unit may be overheated due to the excessive engine cranking. Make sure all the unit functions are turned off and allow the unit to cool down before resuming operation.
  • The vehicle battery may in fault condition and cannot accept starting assistance. The manufacturer recommends taking it to a certified automotive service center for evaluation.
  • Check that the unit has a full charge. Recharge the unit if necessary.

The LED Light will not operate

  • Make sure the USB/LED Power Button has been pressed twice to turn the dual LED Light on.
  • Check that the unit has a full charge. Recharge the unit if necessary.

The Jump-Starter / Power Bank's USB ports will not operate

  • Make sure the USB/LED Power Button has been pressed to turn the USB ports on.
  • If a fault condition exists in either of the USB Ports, the unit will automatically shut down. Refer to the "USB Fault Conditions" section and remedy any faults.
  • Make sure that the total draw the USB device plugged into the USB Port does not exceed 3.1A (5V).
  • Some USB-powered household electronics will not operate with this USB charging/power port. Check the manual of the corresponding electronic device to confirm that it can be used with this type of USB charging/power port.
  • Check that the unit has a full charge. Recharge the unit if necessary.

The 120V AC/USB Charging Adapter's USB port will not operate

  • Make sure you have live AC power to the outlet the 120V AC/USB Charging Adapter is plugged into.
  • Make sure the rating of equipment plugged into the charging adapter's USB port does not exceed 2A continuous.
  • Some household USB-powered electronics will not operate with this USB port. Check the manual of the corresponding electronic device to confirm that it can be used with this type of USB port.

The 12V DC/USB Charging Adapter's USB port will not operate / 12V DC/USB Charging Adapter LED Indicator does not come on

  • Check the connection to the 12 volt DC power source. Make sure there is good contact.
  • Confirm there is functioning DC current.
  • Check the plug fuse in the 12V DC/USB charging adapter. Replace the fuse following the instructions in this manual, if necessary.
  • Make sure the rating of equipment plugged into the charging adapter's USB port does not exceed 2A continuous.
  • Some household USB-powered electronics will not operate with this USB port. Check the manual of the corresponding electronic device to confirm that it can be used with this type of USB port.

If the unit does not operate after taking the steps given above, contact the manufacturer at 1-877-571-2391.

ACCESSORIES

Recommended accessories for use with this unit may be available from the manufacturer. If you need assistance regarding accessories, please contact manufacturer at 1-877-571-2391.

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (21) The use of any accessory not recommended for use with this appliance could be hazardous.

SERVICE INFORMATION

Whether you need technical advice, repair, or genuine factory replacement parts, contact the manufacturer at 1-877-571-2391.

SPECIFICATIONS

Jump-Starter / Power Bank (Certified to ANSI/CAN/UL STD. 2743)

Boost Ampere: 300A Instantaneous

Input: 5V DC, 2A

USB Ports: 5V DC, 3.1A max.

Battery Capacity: Lithium polymer, 11.1V DC

LED Light: 2 white LEDs

Charging Temperature: 32°F to 104°F (0°C to 40°C)

Operating Temperature: –4°F to 104°F (–20°C to 40°C)

12V DC/USB Charging Adapter (Conforms to UL STD. 2089)

Input: 12V DC, 1.1A

Output: 5V DC, 2A

Fuse: 2A

120V AC/USB Charging Adapter (Conforms to UL STD. 62368-1)

Input: 120V AC, 60Hz, 13.3W

Output: 5V DC, 2A

SAFETY GUIDELINES / DEFINITIONS

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (22)
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (23)
Indicates a potentially hazardous situation which, if not avoided, may result in death or serious injury.

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (24)
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (25) Used without the word, indicates a safety related message.

NOTICE: Indicates a practice not related to personal injury which, if not avoided, may result in property damage.

RISK OF UNSAFE OPERATION. When using tools or equipment, basic safety precautions should always be followed to reduce the risk of personal injury. Improper operation, maintenance or modification of tools or equipment could result in serious injury and property damage. There are certain applications for which tools and equipment are designed. Manufacturer strongly recommends that this product NOT be modified and/or used for any application other than for which it was designed. Read and understand all warnings and operating instructions before using any tool or equipment.

READ ALL INSTRUCTIONS

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (26)
Read and understand this instruction manual before using this unit. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury.

IMPORTANT SAFETY INSTRUCTIONS

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (27)
FAILURE TO FOLLOW THE FOLLOWING WARNINGS AND INSTRUCTIONS MAY RESULT IN ELECTRIC SHOCK, FIRE AND/ OR SERIOUS INJURY.

GENERAL SAFETY WARNINGS AND INSTRUCTIONS

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (28)
When using electrical appliances, basic precautions should always be followed, including the following:

  • The jump-starter and supplied charging cable are not toys and cannot be played with as toys. To reduce the risk of injury, close supervision is necessary when these units are used near children.
  • Use only attachments recommended or sold by the manufacturer.

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (29)
To reduce the risk of electric shock:

  • The Smart Cables Controller and Smart Cables Port are always "live"! NEVER insert fingers into the sockets or attempt to disassemble the unit.
  • Do not put the unit in water or other liquid. Do not place or store this unit where it can fall or be pulled into water. Do not expose it to rain, snow or use when wet.
  • Charge indoors only.
  • Use only the USB charging cable supplied by the manufacturer to recharge.

SPECIFIC SAFETY INSTRUCTIONS FOR LITHIUM BATTERIES

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (30)
To reduce the risk of fire, electric shock, burst hazard, or injury to persons or property: Lithium batteries are small, compact and ideal for providing long-lasting power to this unit. However, they must be used and charged properly. Improper use can result in serious injury, fire, or death.

  • Lithium batteries can explode in the presence of a source of ignition. Do not use the product in the presence of an open flame.
  • Do not place this lithium battery powered unit in fire or apply heat to it.
  • Do not subject this lithium battery powered unit to strong impacts or shocks. The battery in this unit contains safety and protection devices which, if damaged, may cause the battery to generate heat, rupture or ignite.
  • Do not expose this lithium battery powered unit to water or salt water, or allow the battery to get wet.
  • Avoid storing this lithium battery powered unit in the basement, bathroom or other areas of the house that are or may become wet or humid or where moisture may concentrate.
  • Do not leave this lithium battery powered unit in direct sunlight, or use or store the unit inside cars in hot weather. Doing so may cause the battery to generate heat, rupture, or ignite. Using the battery in this manner may also result in a loss of performance and a shortened life expectancy.
  • Never charge this unit near heat or flammable objects.
  • NEVER THROW WATER ON A BURNING LITHIUM BATTERY! If a lithium battery does catch on fire, it will burn even more violently if it comes in contact with water or even moisture in the air. A fire extinguisher must be used.

Battery Charging and Capacity

This unit is delivered in a partially charged state – you must fully charge it before using it for the first time.

When stored at room temperature with a full charge, lithium batteries will begin to discharge from the time they are manufactured, even when unused. Deep discharges also decrease their capacity. Battery life can be extended by the following:

  • Charge battery to full capacity before storage.
  • Store this unit at temperatures between 5°C and 20°C (41°F and 68°F).
  • Never discharge the battery fully.
  • Charge after each use.
  • Always charge at least once every 3-6 months if not in frequent use to prevent overdischarge.

Transportation of Lithium Batteries

  • Always check all applicable local, national, and international regulations before transporting a unit containing a lithium battery.
  • Transporting an end-of-life, damaged, or recalled battery may, in certain cases, be specifically limited or prohibited.

SPECIFIC SAFETY INSTRUCTIONS FOR JUMP-STARTERS

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (31)
Burst hazard

Do not use the unit for charging dry-cell batteries that are commonly used with home appliances. These batteries may burst and cause injury to persons and damage property. Use the unit for charging/boosting a lead-acid battery only. It is not intended to supply power to a low-voltage electrical system other than in a starter-motor application.

  • Use of an attachment not supplied, recommended or sold by manufacturer specifically for use with this unit may result in a risk of electrical shock and injury to persons.

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (32)
Risk of explosive gases

  • Working in the vicinity of a lead acid battery is dangerous. Batteries generate explosive gases during normal battery operation. For this reason, it is of the utmost importance that each time before using the jump-starter you read this manual and follow instructions exactly.
  • To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in the vicinity of the battery. Review cautionary markings on these products and on the engine.

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (33)
To reduce the risk of injury or property damage:

  • NEVER ATTEMPT TO JUMP-START OR CHARGE A FROZEN BATTERY.
  • NEVER connect this product to a positive grounded vehicle.
  • Do not operate unit with damaged cord or plug; or if the unit has received a sharp blow, been dropped, or otherwise damaged in any way. Do not disassemble the unit; return it to the manufacturer when service or repair is required. Opening the unit may result in a risk of electric shock or fire, and will void warranty.
  • Make sure the cord is located so that it will not be stepped on, tripped over or otherwise subjected to damage or stress.
  • Do not leave the unit unattended while in use.
  • Pull by the plug rather than the cord when disconnecting the USB Charging Cable.
  • Vehicles that have on-board computerized systems may be damaged if vehicle battery is jump-started. Before jump-starting, read the vehicle's owner's manual to confirm that external-starting assistance is suitable.
  • This system is designed to be used only on vehicles with a 12 volt DC lead-acid battery system. Do not connect to a 6 volt or 24 volt battery system.
  • Excessive engine cranking can damage the vehicle's starter motor. If the engine fails to start after the recommended number of attempts, discontinue jump-start procedure and look for other problems that need to be corrected.
  • Do not use this battery booster on a watercraft. It is not qualified for marine applications.
  • To reduce the risk of fire, make sure that the 12 volt outlet is free of debris and the adaptor plug fits tightly in the outlet.
  • Never allow battery acid to come in contact with this unit.
  • Do not operate this unit in a closed area or restrict ventilation in any way.

INSTRUCTIONS PERTAINING TO THE 12V DC/USB CHARGING ADAPTER

NOTICE – To avoid the risk of property damage:

  • The 12 Volt DC charging adapter must only be connected to batteries with a nominal output voltage of 12 volts. The unit will not operate from a 6 volt battery and will sustain permanent damage if connected to a 24 volt battery.
  • Always connect the 12 volt DC/USB charging adapter to the 12 volt DC power source before plugging any devices into it.

INSTRUCTIONS PERTAINING TO THE USB PORTS

  • Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (34)
    Some household USB-powered electronics will not operate with the USB ports provided with this device. Check the manual of the corresponding electronic device to confirm that it can be used with this type of USB port.
  • The USB ports do not support data communication. They only provide power to an external USB powered device (5V DC/3.1A maximum using the dual USB ports on the unit, or 5V DC/2A using the USB ports on the AC/USB or DC/USB Charging Adapters). Make sure the rating of equipment plugged into the USB port does not exceed the amperage stated.
  • Always connect the appropriate charging adapter to either the 120V AC or 12V DC power source before plugging any devices into it.
  • Do not attach USB hubs allowing connection of multiple personal electronic devices to any of the USB ports on the charging adapters.
  • Do not insert foreign objects into the USB Ports.

PERSONAL SAFETY

  • When working with lead acid batteries, always make sure immediate assistance is available in case of accident or emergency.
  • Always have protective eyewear when using this product: contact with battery acid may cause blindness and/or severe burns. Be aware of first aid procedures in case of accidental contact with battery acid.
  • Have plenty of fresh water and soap nearby in case battery acid contacts skin.
  • Remove personal metal items such as rings, bracelets, necklaces and watches when working with a lead acid battery. A lead acid battery can produce a short circuit current high enough to weld a ring, or similar metal object, to skin causing a severe burn.
  • Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to persons.
  • Be extra cautious to avoid dropping a metal tool onto the battery. It might spark or short-circuit the battery or another electrical part, and that may cause an explosion.
  • Never smoke or allow a spark or flame in vicinity of vehicle battery, engine or battery charger.

SKIN: If battery acid contacts skin or clothing, wash immediately with soap and water for at least 10 minutes. If redness, pain, or irritation occurs, seek immediate medical attention.

EYES: If battery acid comes in contact with eyes, flush eyes immediately, for a minimum of 15 minutes and seek immediate medical attention.

LCD liquid crystal display: If liquid crystal comes in contact with your skin: Wash area off completely with plenty of water. Remove contaminated clothing. If liquid crystal gets into your eye: Flush the affected eye with clean water and then seek medical attention. If liquid crystal is swallowed: Flush your mouth thoroughly with water. Drink large quantities of water and induce vomiting. Then seek medical attention.

SAVE THESE INSTRUCTIONS

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (35)
To reduce the risk of injury: Follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use with this unit. Review cautionary markings on these products and on engine.

STANLEY® AND THE STANLEY® LOGO ARE REGISTERED TRADEMARKS OF STANLEY BLACK + DECKER INC. OR ONE OF ITS AFFILIATES, AND ARE USED UNDER LICENSE.

Imported by Baccus Global LLC,
621 NW 53rd St., Suite 450, Boca Raton, FL 33487
www.baccusglobal.com 1-877-571-2391

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (36)

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual

Stanley SS4LS - 600 Peak Amp Lithium Ion Power Station/Jump Starter/Power Bank Manual (2024)
Top Articles
Latest Posts
Recommended Articles
Article information

Author: Aracelis Kilback

Last Updated:

Views: 5273

Rating: 4.3 / 5 (64 voted)

Reviews: 87% of readers found this page helpful

Author information

Name: Aracelis Kilback

Birthday: 1994-11-22

Address: Apt. 895 30151 Green Plain, Lake Mariela, RI 98141

Phone: +5992291857476

Job: Legal Officer

Hobby: LARPing, role-playing games, Slacklining, Reading, Inline skating, Brazilian jiu-jitsu, Dance

Introduction: My name is Aracelis Kilback, I am a nice, gentle, agreeable, joyous, attractive, combative, gifted person who loves writing and wants to share my knowledge and understanding with you.